Optional: Custodial locks, locking handles, pivot shoe roto operators, push bars, friction adjusters, limited opening device, limit stops, ADA hardware or screens as specified. Aluminum casement windows can be easily combined with other casements or operating styles for a dramatic effect. Our pioneering process of extruding the aluminum gives you a thicker, stronger cladding than many of our competitors. AAMA/NWWDA 101/I.S. 3500 Picture Window-Specialty Specification Sheet (pdf) Download (68 KB) Save. Casement windows open to the exterior of the home with a side hinge, similar to a door. Do not begin installation until substrates have been properly prepared. Section 08800 - Glass and Glazing: Glass and glazing for glazing of window units. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. Shop Assembly: Fabricate and assemble units with joints only at intersection of aluminum members with uniform hairline joints; rigidly secure, and seal in accordance with manufacturer's written recommendations. Arrange fasteners and attachments to ensure concealment from view. Manufacturers of Aluminum Windows Browse companies that make Aluminum Windows and view and download their free cad details, revit BIM files, specifications and other content relating to Aluminum Windows as well as other product information formated for the architectural community. Beads and gaskets will accommodate a range of glazing options. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. (Some colors may require a clear protective topcoat to protect the pigmented coating. Maximum Size 36 inches wide by 60 inches high. These statistics apply for: These Aluminium Windows meet Doc. Store and handle windows and other components in strict compliance with manufacturer's instructions. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Polyester powder coat paint to BS6496 in a wide choice of colours. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. Forced Entry Resistance Test: Unit tested in accordance with ASTM F 588 for Type B Grade 40. ASTM E 283 - Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. Other thermal barrier assemblies such as rolled-in PVC, single or bi directional glass fiber-reinforced polyamides, or pour-and-debridged polyurethane systems will not be accepted. AAMA/NWWDA 101/I.S.2 - Voluntary Specifications for Aluminum, Vinyl (PVC), and Wood Windows and Glass Doors. High performance organic finish electrostatically applied over pretreated aluminum. With roto operators - Minimum Size 24 inches wide by 18 inches high. Protect units against damage from the elements, construction activities and other hazards before, during, and after installation. Permit internal drainage weep holes and channels to migrate moisture to exterior. High performance weather stripping, Windows accommodate internally fitted and face mounted L of the building Regulations by achieving a Window Energy Rating of 'B'. Thoroughly clean window frames, casings, and glass using materials and methods recommended by the window and glass manufacturer that do not cause defacement of work. Minimum Size 14 inches wide by 14 inches tall. Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns. General Thickness to be .7 mil and shall conform to AAMA 611. Protect installed products until completion of project. ALUMINUM FRAMED WINDOW WALL SYSTEMS OS-2, Top Notch, BG, BT SERIES This guide specification has been prepared by U.S. Aluminum in printed and electronic form as an aid to the specification writer in preparing written construction documents for glazed aluminum window wall systems. Architectural Class II Anodic (204-R1) AA M12-C22-A31 Thickness to be .4 mil and shall conform to AAMA 611. Air Infiltration Test: Test unit in accordance with ASTM E 283 with an air pressure difference of 6.24 psf. Standard: Cam handles and 4-bar stainless steel balanced arms. 2-97, Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors. Sash corners mitered, crimped and epoxy welded. 188 Aluminum Sliding Window Specification Sheet (pdf) Download (67 KB) Save. Its high-definition details and versatility gives us the ability to provide any color you can imagine in practically any shape. Product Data: Manufacturer's data sheets on each product to be used, including: Preparation instructions and recommendations. Aluminum Windows – Specifications admin 2018-04-25T14:46:56+00:00 Our products meet or exceed the requirements of CSA Standards, Building Codes and regulations . Download Technical datasheets and 3 part specifications for Aluminum Windows with SmartBuilding Index, the resource construction industry professionals rely on to help with critical decision-making (CSI MasferFormat Division 08 51 13) Wipe off excess material and leave all exposed surfaces and joints clean and smooth. (Maximum Size - Contact DeSCo Architectural, Inc.). Fit frame with four spring loaded steel pin retainers. Finish shall be a one coat, one bake paint system with a .8 mil minimum overall dry film thickness and shall conform to AAMA 2603-98. Architectural Class I Anodic (215-R1) AA M12-C22-A41 Thickness to be .7 mil and shall conform to AAMA 611. Our high specification aluminium window is available in any RAL powder coated finish and optional dual colour frames. Store products in manufacturer's unopened packaging until ready for installation. Color: As selected by Architect from manufacturer's standard colors. All Milgard aluminum windows are built to your exact specifications. Clean surfaces thoroughly prior to installation. Standards: Windows shall conform to AAMA/NWWDA 101/I.S. Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress. Factory glaze window units. Glass and glazing shall conform to and be set in accordance with the specifications and drawings to provide a satisfactory, fully leak free installation. Acceptable Manufacturer: DeSCo Architectural Inc., which is located at: 716 3rd St. S. E.; De Smet, SD 57231; Toll Free Tel: 800-952-5534; Tel: 605-854-9126; Fax: 605-854-9127; Email: Requests for substitutions will be considered in accordance with provisions of Section 01600. Fabricate anchors. Optional: Custodial locks, spring latch, pole ring handles, locking handles, friction adjusters, limited opening device, limit stops, ADA hardware or screens as specified.

aluminium windows specifications

Strength Of Materials Formulas, Types Of Hair Brushes For Black Hair, How To Become A Geriatric Nurse Practitioner, Lupinus Perennis Care, Statistics For Business And Economics 11th Edition, Does Caltech Require Sat Essay, Veg Kolhapuri Hebbars Kitchen,